首页> 外文会议>World congress on medical physics and biomedical engineering;International congress of the IUPESM >FIRST ASSESSMENT OF A NOVEL IGRT DEVICE FOR STEREOTACTIC BODY RADIATION THERAPY
【24h】

FIRST ASSESSMENT OF A NOVEL IGRT DEVICE FOR STEREOTACTIC BODY RADIATION THERAPY

机译:新型IGRT装置用于定性身体放射治疗的首次评估

获取原文

摘要

Introduction: A new device has been developed for image-guided Stereotactic Body Radiation Therapy (SBRT). TheVero SBRT System (known as "TM2000"in Japan), a joint product of MHI (Mitsubishi Heavy Industries Ltd., Tokyo, Japan) and Brain LAB (BrainLAB AG, Feldkir-chen, Germany) utilizes a rotating, rigid ring structure to integrate a beam delivery platform and image guidance systems. An inline 6 MV C-band LINAC with MLC is mounted on orthogonal gimbals that are in turn built into the ring structure. An electronic portal imaging device (EPID) and two kV imaging devices are also integrated in the ring. Opening commissioning measurements and stereotactic "hidden target" tests were performed to assess dosimetric and targeting characteristics as well as clinical capabilities of this SBRT dedicated device.Materials and Methods: Percent depth dose curves and beam profiles were measured in a water phantom and subsequently analyzed in accordance with industry standards. Additional characteristics including dose and dose rate linearity, relative output with varying field size, and output constancy with gantry angle were also evaluated. A commercial stereotactic phantom (LucyTM, Standard Imaging, Middleton, WI) was used to assess end-to-end localization accuracy of the image guidance system (through a "hidden-target" test) and for a comparison of absolute and relative dose against treatment planning calculations.Results: The essential characteristics of the Vero are commensurate with modern stereotactic requirements. Dosimetric characteristics are similar to other dedicated SRS/SBRT units, and end-to-end localization tests indicate sub-millimeter targeting accuracy.Conclusion: We have conducted preliminary commissioning and assessment of a novel device for image guided SBRT. Additionally, the integration of a gimbaled treatment beam, 2D and 3D imaging, tracking capabilities and real-time feedback provide unique opportunity to develop and implement advanced SBRT delivery techniques.
机译:简介:已开发出一种用于图像引导立体定向放射治疗(SBRT)的新设备。 Vero SBRT系统(在日本称为“ TM2000”)是三菱重工(日本东京的三菱重工有限公司)和Brain LAB(德国费尔德基尔辰的BrainLAB AG)的联合产品,利用旋转的刚性环结构来制造集成了光束传输平台和图像引导系统。带有MLC的直列6 MV C波段LINAC安装在正交万向架上,这些万向架又内置在环形结构中。环形中还集成了电子门禁成像设备(EPID)和两个kV成像设备。进行了开放式调试测量和立体定向“隐藏目标”测试,以评估该SBRT专用设备的剂量和瞄准特性以及临床能力。 材料和方法:在水模中测量深度剂量曲线的百分比和射束轮廓,然后根据行业标准进行分析。还评估了其他特性,包括剂量和剂量率线性,具有不同场大小的相对输出以及具有龙门架角度的输出恒定性。商业立体定位幻影(LucyTM,Standard Imaging,Middleton,WI)用于评估图像引导系统的端到端定位精度(通过“隐藏目标”测试),并比较绝对剂量和相对剂量与治疗计划的计算。 结果:Vero的基本特征与现代立体定向要求相称。剂量学特性与其他专用SRS / SBRT单元相似,端到端定位测试表明亚毫米目标精度。 结论:我们已经对图像引导SBRT的新型装置进行了初步调试和评估。此外,万向架治疗光束,2D和3D成像,跟踪功能和实时反馈的集成为开发和实施高级SBRT交付技术提供了独特的机会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号