The authors have developed a polymer insulator with built-in ZnO elements used for 22kV overhead distribution lines, which also functions as an arrester. Research has been made into how lightning faults can be prevented by using an insulator with a low insulation level, aiming to reduce distribution line construction and operation costs. The developed device met our initial standards. A unique mechanism applying a newly devised FRP-metal connection technique and pressure-release function is incorporated into the device. The results of both performance and pressure-release testing revealed that this pole-mounted insulator drastically contributes to lightning protection of the distribution line, while its electrical/mechanical properties are satisfactory, being equivalent to those of traditional ceramic insulators. However, the long-term reliability of polymer insulators in complex natural environmental conditions has not been adequately assessed, resulting in limitations of their widespread use. Given this situation, a 5,000-hour complex environmental test was conducted to measure leakage current. The results showed a little erosion on the polymeric material surface, but leakage current did not increase. No specific problems with the insulation's performance were seen. These experimental results revealed that the devised insulator's adequate performance could allow it to be put into practical use.
机译:作者已经开发出一种聚合物绝缘体,该绝缘体具有用于22kV架空配电线路的内置ZnO元素,还可以用作避雷器。已经进行了关于如何通过使用具有低绝缘水平的绝缘子来防止雷电故障的研究,旨在减少配电线路的构造和运营成本。开发的设备符合我们的初始标准。该设备采用了采用新设计的FRP-金属连接技术和压力释放功能的独特机制。性能和压力释放测试的结果表明,这种安装在杆上的绝缘子极大地有助于配电线路的防雷,同时其电气/机械性能令人满意,与传统的陶瓷绝缘子相当。但是,聚合物绝缘子在复杂的自然环境条件下的长期可靠性尚未得到充分评估,从而限制了它们的广泛使用。在这种情况下,进行了5,000小时的复杂环境测试以测量泄漏电流。结果显示在聚合物材料表面上有一点腐蚀,但是漏电流没有增加。没有发现绝缘性能的具体问题。这些实验结果表明,设计的绝缘子具有足够的性能,可以使其实用化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号