首页> 外文会议>Conference on optical sensors >ETM cold-focal-plane thermal vaccum testing
【24h】

ETM cold-focal-plane thermal vaccum testing

机译:ETM冷焦面热真空测试

获取原文
获取外文期刊封面目录资料

摘要

er describes the tests performed on the enhanced thematic mapper (ETM) cold focal plane array (CFPA) after it was fully characterized in a test dewar and before the full instrument integration. The cold focal plane array was first integrated onto the radiative cooler with the thermal switch open so there is no thermal conduction between the radiator cold stage and the CFPA. A Joule-Thompson cooler was used to cool the CFPA during the before- and after-vibration tests. After these two bench-level tests the thermal switch was closed and the CFPA cooler assembly was prepared for the final thermal-vacuum chamber testing. This test encompasses two major goals. The first one is to make certain that the cooler performance meets specifications. This was done with the cooler facing a simulated cold space background and proper thermal loads were impressed. The second is to adjust the band 6 (PC HgCdTe) preamp circuits so maximum dynamic range can be realized during the actual flight environment. The work was performed while the author was affiliated with Santa Barbara Research Center.
机译:ER描述了在增强专题映射器(ETM)冷焦平面阵列(CFPA)上进行的测试在测试露天度和完整仪器集成之前进行的。冷焦平面阵列首先与热开关打开,以便打开辐射冷却器,因此散热器冷级和CFPA之间没有热导通。 joule-thompson冷却器用于在振动前和振动前测试期间冷却CFPA。在这两个台阶测试之后,关闭热开关,并为最终的热真空室测试制备CFPA冷却器组件。该测试包括两个主要目标。第一个是确保冷却器性能符合规格。这是通过面向模拟的冷空间背景的冷却器完成的,并且对其印象得出了适当的热载荷。第二代是调整带6(PC HGCDTE)前置放大器电路,以便在实际飞行环境中实现最大动态范围。作者隶属于圣巴巴拉研究中心的作品。