首页> 外文会议>Ozone world congress >Pilot Scale Evalaution of Ozoen and other Drinking Water Disinfectants usign Mutagenicity Testing
【24h】

Pilot Scale Evalaution of Ozoen and other Drinking Water Disinfectants usign Mutagenicity Testing

机译:臭氧和其他饮用水消毒剂致突变性的中试评估

获取原文

摘要

Mutagenicity produced by the oxidatns chlorine, chloramines, chlorine dioxide and ozone when used in drinking water treatment was examined in a pilot scale studyconducted at Edmonton, Canada. Both the Ames test, nad a yeast assay usign Saccharomyces cerevisiae (strain D7144-2) were employed. In the Ames test, chlorination produced mutagenicity the most frequently; samples obtained following ozonation were rarely mutagenic. In the yeast assay, mutagenicity was seen only infrequently. Granular activated carbon effectively removed mutagenicity for a logn period of time.
机译:在加拿大埃德蒙顿进行的一项中试研究中研究了氧化氯,氯胺,二氧化氯和臭氧在饮用水处理中产生的致突变性。既使用了Ames试验,又使用了酵母(Saccharomyces cerevisiae)酵母菌株(菌株D7144-2)。在Ames试验中,氯化作用最常引起诱变。臭氧化后获得的样品很少致突变。在酵母测定中,很少见到致突变性。颗粒状活性炭可在一段登录时间内有效地消除诱变性。