To measure and characterize power loss and efficiency of highly efficient power semiconductors such as SiC MOSFET modules, a simple and accurate inverter power loss measurement method is proposed. The technique is based on electrical measurement of DC input power and AC output current of an inductor load. High accuracy can be achieved by using low-loss air-core inductor as load. The measurement results are meaningful for SiC inverters in practical conditions operating at synchronous rectification, since the loss is independent on load power factors. The measurement error is minimized because the output real power is designed to be close to the SiC module loss and the Litz-wire air-core inductor avoids the use of complex core loss models. The method is validated for SiC phase-leg inverter. Experimental results are presented and validated on a SiC phase module with 620V DC input and up to 180A output. The inverter loss measurement error is analyzed based on test data.
机译:为了测量和表征功率损耗和高效功率半导体的功率损耗和效率,如SiC MOSFET模块,提出了一种简单准确的逆变器功率损耗测量方法。 该技术基于电感器负载的DC输入功率和AC输出电流的电测量。 通过使用低损耗空心电感器作为负载可以实现高精度。 测量结果对于在同步整流运行的实际条件下的SiC逆变器是有意义的,因为损耗是独立于负载电源因素的影响。 测量误差最小化,因为输出实际功率被设计为接近SIC模块损耗,并且LITZ线空心电感器避免使用复杂的核心损耗模型。 该方法是针对SiC相位腿逆变器验证的。 在具有620V直流输入和高达180A输出的SIC相模块上呈现和验证了实验结果。 基于测试数据分析逆变器损耗测量误差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号