首页> 外文会议>IEEE MTT-S International Microwave Symposium Digest >Millimeter Wavelength Solid State Oscillator AM and FM Noise
【24h】

Millimeter Wavelength Solid State Oscillator AM and FM Noise

机译:毫米波固态振荡器AM和FM噪声

获取原文

摘要

A comparison of difficulty for AM and FM noise measurements at millimeter and centimeter wavelengths explains why few FM noise measurements and even fewer AM noise measurements have been reported. The AM noise measurement should be made to prove that AM noise can be neglected and to learn about the oscillator diode noise measure, M. Since millimeter wavelength solid state oscillators are relatively noisy, we show that a simple transmission line discriminator is adequate for measuring both AM and FM noise. Data will be presented for several oscillators in the most used portions of the millimeter wave bands.
机译:比较毫米和厘米波长处的AM和FM噪声测量的难度,可以解释为什么报告了很少的FM噪声测量甚至更少的AM噪声测量。应该进行AM噪声测量,以证明可以忽略AM噪声,并了解振荡器二极管的噪声测量M。由于毫米波长固态振荡器的噪声相对较大,因此我们证明了简单的传输线鉴别器就足以同时测量这两种噪声。 AM和FM噪声。将在毫米波段最常用的部分中显示几个振荡器的数据。