首页> 外文会议>IEEE International Symposium on Electromagnetic Compatibility >Predicting TEM Cell Measurements from Near Field Scan Data
【24h】

Predicting TEM Cell Measurements from Near Field Scan Data

机译:预测来自近场扫描数据的TEM单元测量

获取原文

摘要

A procedure is proposed for predicting TEM cell measurements from near field scans by modeling near-field scan data using equivalent sources. The first step in this procedure is to measure the tangential electric and magnetic fields over the circuit. Electric and magnetic fields are estimated from probe measurements by compensating for the characteristics of the probe. An equivalent magnetic and electric current model representing emissions is then generated from the compensated fields. These equivalent sources are used as an impressed source in an analytical formula or full wave simulation to predict measurements within the TEM cell. Experimental verification of the procedure using a microstrip trace and clock buffer show that values measured in the TEM cell and calculated from near field scan data agree within a few decibels from 1 MHz to 1 GHz.
机译:提出了一种通过使用等效源建模近场扫描数据来预测近场扫描的TEM小区测量的过程。该过程的第一步是测量电路上的切向电场和磁场。通过补偿探针的特性,从探测测量估计电场和磁场。然后从补偿场产生代表发射的等效磁性和电流模型。这些等效源被用作分析公式或全波模拟中的墨留下的源,以预测TEM小区内的测量。使用微带轨迹和时钟缓冲器的程序的实验验证表明,在TEM小区中测量的值并由近场扫描数据计算的值在少数分贝中同意,从1 MHz到1 GHz。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号