Smart substations are an integral part of a smart grid. There are different new smart devices and components in the key systems of the substations. In order to study the impact of lightning to smart substations, simulation modeling will be used to analyze the damages caused by lightning and the lightning protection level. According to the analysis, the impact of lightning to smart substations differs from that to conventional substations in the following three aspects: the number of cables is reduced; there are short cables; and there are smart devices at the outdoor switching station. According to the calculation for an 110kV smart substation, high-amplitude lightning directly striking lightning rods is the main cause of disruption to the devices of smart substations; the impact of low amplitude lightning to smart substations will be considered only when it strikes smart substations of 500kV or higher; where there are line arresters and intact metal shells, the lightning intruding surge and inductive lightning will not affect the equipment of the station.
机译:智能变电站是智能电网的一个组成部分。变电站的关键系统中有不同的新智能设备和组件。为了研究闪电对智能变电站的影响,仿真建模将用于分析雷电引起的损坏和防雷水平。根据分析,雷电对智能变电站的影响与以下三个方面中的传统变电站不同:电缆数量减少;有短的电缆;户外开关站有智能设备。根据110kV智能变电站的计算,直接引人注目的避雷针的高幅度闪电是对智能变电站器件中断的主要原因;当它击中500kV或更高的智能变电站时,才会考虑低振幅闪电对智能变电站的影响;在有线避雷器和完整的金属壳中,雷电侵入浪涌和电感闪电不会影响车站的设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号