Thermal design in electronic packaging is driven by the maximum allowable junction temperature of a CPU. An inadequate thermal design that underestimates the junction temperature may adversely impact the electrical performance of the CPU, making predicting the junction temperature a crucial step in package and system thermal design. A numerical model of a heat sink and thermal test package with a uniform and non-uniform power dissipation was created and used to predict their temperatures. The uniform power dissipation case was used to calibrate the numerical model's TIM2 thermal impedance. In the non-uniform power cases, the maximum heat flux was over four times higher than the average heat flux. The numerical analysis results in the non-uniform power cases yielded junction temperatures within 2 degrees of the measured values. The heat sink used in the tests as well as numerically modeled contained a vapor chamber base and a plate heat sink. Three different heat sink modeling approaches were used, including: detailed modeling of the heat sink, effective convection coefficient heff, and effective thermal conductivity keff. Test data was used to establish the effective heat transfer coefficient and effective thermal conductivity. A simplified heat sink numerical model allows the computational grid density to be significantly reduced, resulting in fast convergence. Alternate heat sink designs were also considered.
机译:电子封装中的散热设计由CPU的最高允许结温决定。散热设计不足会低估结温,可能会对CPU的电气性能产生不利影响,因此,预测结温是封装和系统散热设计中的关键步骤。创建了具有均匀和非均匀功耗的散热器和热测试套件的数值模型,并将其用于预测其温度。均匀功耗情况用于校准数值模型的TIM2热阻。在功率不均匀的情况下,最大热通量比平均热通量高四倍以上。数值分析结果表明,在功率不均匀的情况下,结温在测量值的2度以内。测试中使用的散热器以及经过数值建模的散热器均包含蒸气室基座和板式散热器。使用了三种不同的散热器建模方法,包括:散热器的详细建模,有效对流系数heff和有效导热系数keff。测试数据用于建立有效的传热系数和有效的热导率。简化的散热器数值模型使计算网格密度显着降低,从而实现了快速收敛。还考虑了备用散热器设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号