An approximate inverse system control based active DC filter applied in HVDC

机译:基于近似逆系统控制的有源直流滤波器在HVDC中的应用

获取原文

摘要

This paper details the principle of the active DC filter (ADF) applied in the high-voltage direct current (HVDC) system, and proposes a novel composite control strategy composed of an approximate inverse system open-loop control and a closed-loop control. The harmonic source current and the compensation current are respectively measured as the reference signal and the feedback signal. A filter bank is adopted to compose the approximate inverse system controller, which is the key controller in the composite control strategy. Both results of simulations based on PSCAD and experiments on a 30kVA HVDC system validate that the ADF adopting the proposed control strategy is able to cancel the harmonics efficiently because of the advantages of the approximate inverse system controller and the absence of the extraction of weak signal from noise. The work is expected to build the prototype of the future industrial equipment.
机译:本文详细介绍了在高压直流(HVDC)系统中应用有源直流滤波器(ADF)的原理,并提出了一种由近似逆系统开环控制和闭环控制组成的新型复合控制策略。分别测量谐波源电流和补偿电流作为参考信号和反馈信号。采用滤波器组组成近似逆系统控制器,它是复合控制策略中的关键控制器。基于PSCAD的仿真结果和在30kVA高压直流输电系统上进行的实验均证明,采用近似控制系统的ADF的优点在于,它具有近似逆系统控制器的优点,而且无需从中提取弱信号,因此,采用建议控制策略的ADF能够有效地消除谐波噪音。这项工作有望构建未来工业设备的原型。