A new current mirror structure using a non-rectangular dual-drain device with a shared channel to reduce the matching sensitivity to linear parameter gradients is introduced. The new structures are compared with conventional common centroid layouts for threshold voltage gradients at all angles across the active area of a mirror. Results show that in some applications, significant improvement in matching characteristics with the proposed non-rectangular structures over what is achievable with conventional layout techniques can be achieved.
机译:引入了一种新的电流镜结构,该结构使用具有共享通道的非矩形双漏极器件来降低对线性参数梯度的匹配灵敏度。将该新结构与常规常见的质心布局进行比较,以在整个反射镜的有效区域上的所有角度上获得阈值电压梯度。结果表明,在某些应用中,与传统的布局技术相比,与拟议的非矩形结构的匹配特性可实现显着改善。