首页> 外文会议> >Behavior of medium voltage EPR cables designed for operation under high electrical fields
【24h】

Behavior of medium voltage EPR cables designed for operation under high electrical fields

机译:专为在高电场下运行而设计的中压EPR电缆的性能

获取原文

摘要

Medium voltage cable incorporating high stress design with the appropriate EPR insulation demonstrated a significant safety margin when subjected to both AEIC CS6-87 and CS6-96 qualification test. This indicates that high stress designed EPR cables can operate on typical utility network systems as PILC replacements. This is confirmed by the AEIC design of l/O AWG, 35 kV, 8.76 mm (345 mil) insulation, which has been in operation for over 20 years with a excellent service record. The test results also show that Weibull statistical analysis can be used to assess and verify a particular design of medium voltage cables.
机译:在接受AEIC CS6-87和CS6-96资格测试的同时,结合了高应力设计和适当EPR绝缘的中压电缆表现出显着的安全裕度。这表明高应力设计的EPR电缆可以作为PILC的替代品在典型的公用网络系统上运行。 AEIC设计的L / O AWG,35 kV,8.76 mm(345 mil)绝缘,已经使用了20多年,并具有出色的服务记录。测试结果还表明,威布尔统计分析可用于评估和验证中压电缆的特定设计。

著录项