Lamination core loss measurements in machines operating with PWM or nonsinusoidal excitation

机译:使用PWM或非正弦激励的电机中的叠片铁损测量

获取原文

摘要

Variable speed drives (VSDs) are becoming standard supplies for motors in industries because of their benefits in increased process control and energy savings. The benefits of employing a VSD are derived at a cost of increased core losses and motor temperature rise. Core loss measurements with sinusoidal supplies are guided by international standards. However, there are currently no international standards for the fast growing variable frequency supplies and the associated core losses. In this paper, a test bench for core loss measurements under variable frequency supplies proposed by A. Boglietti et al. (1997) is adopted. Work reported in this paper serves to validate the proposal and extends the test bench proposal to switched reluctance motor (SRM) lamination core loss measurements. An Epstein frame was used for direct core loss measurements. The methods and test bench used are detailed in the paper, along with test results.
机译:变速驱动器(VSD)由于在提高过程控制和节能方面的优势,已成为工业电动机的标准供应商。使用VSD的好处是以增加铁芯损耗和电机温度升高为代价的。使用正弦曲线电源进行铁心损耗测量应遵循国际标准。但是,对于快速增长的变频电源及其相关的磁芯损耗,目前还没有国际标准。在本文中,A。Boglietti等人提出了在变频电源下进行铁损测试的测试台。 (1997)被采用。本文中报道的工作可用于验证该建议,并将测试台建议扩展到开关磁阻电机(SRM)叠片铁损测量。 Epstein框架用于直接铁损测量。本文详细介绍了使用的方法和测试台以及测试结果。