This paper proposes a novel control strategy to improve input power factor of the single phase diode rectifier. The proposed power converter doesn't need energy storage units such as an electrolytic capacitor or a reactor. So there are many ripples across the DC-bus voltage and then, the input power factor can be improved. The proposed system consists of an only diode rectifier, a small film DC capacitor, a three phase inverter and an interior permanent magnet (IPM) synchronous motor. The basic ideas are based on two following operations. First, the inverter's controlled synchronous with the DC-bus ripple voltage by field-weakening method. The other is direct active power control from the source to the motor without smoothing the DC-bus voltage. This paper shows that the proposed method can obtain the input power factor over 97% by experimental tests, and realize the small size and the long life of the system.
机译:本文提出了一种新颖的控制策略,以提高单相二极管整流器的输入功率因数。提出的功率转换器不需要诸如电解电容器或电抗器之类的能量存储单元。因此,直流母线电压上会有许多纹波,然后可以改善输入功率因数。拟议的系统仅由一个二极管整流器,一个薄膜直流电容器,一个三相逆变器和一个内部永磁体(IPM)同步电动机组成。基本思想基于以下两个操作。首先,通过弱磁方法与直流母线纹波电压同步控制逆变器。另一个是从电源到电动机的直接有功功率控制,而不会使直流母线电压平滑。本文表明,该方法通过实验测试,可获得97%以上的输入功率因数,实现了系统的小尺寸和长寿命。