首页> 外文会议> >EXPERIMENTAL STUDY OF A NEW DOUBLE-CAPILLARY TUBE REFRIGERATION SYSTEM OF CHEST REFRIGERATOR
【24h】

EXPERIMENTAL STUDY OF A NEW DOUBLE-CAPILLARY TUBE REFRIGERATION SYSTEM OF CHEST REFRIGERATOR

机译:一种新型双腔管制冷机的实验研究

获取原文

摘要

A new BCD-192 chest refrigerator with the double-capillary tube in tandem refrigeration cycle has been designed and produced. According to the correlative requirement of the national standard, many experimental researches on the performances of the tandem double-capillary tube refrigeration cycle respectively adopting refrigerant R12, R134a and R600a have been done detailedly. The experiment results show that in contrast to the energy consumptions of the BCD-192 chest refrigerator with the single-capillary refrigeration system, the energy consumptions of the BCD-192 chest refrigerator with the new refrigeration system decrease almost by 8%, 7.5% and 8.3%, when refrigerant R12, R134a and R600a are adopted respectively.
机译:设计并生产了一种新的BCD-192箱式冰箱,它具有双毛细管串联制冷循环。根据国家标准的相关要求,对分别采用制冷剂R12,R134a和R600a的串联双毛细管制冷循环的性能进行了许多实验研究。实验结果表明,与采用单毛细管制冷系统的BCD-192胸式冰箱的能耗相比,采用新型制冷系统的BCD-192胸式冰箱的能耗分别降低了8%,7.5%和7.5%。当分别采用制冷剂R12,R134a和R600a时为8.3%。