首页> 外文会议> >HEAT LOSSES FROM PIPES CONNECTED TO HOT WATER STORAGE TANKS
【24h】

HEAT LOSSES FROM PIPES CONNECTED TO HOT WATER STORAGE TANKS

机译:连接到热水储罐的管道造成的热损失

获取原文

摘要

The heat loss from pipe connections at the top of hot water storage tanks with and without a heat trap is investigated theoretically and compared to similar experimental investigations. Computational Fluid Dynamics (CFD) is used for the theoretical analysis. The investigations show that the heat loss from an ideally insulated pipe connected to the top of a hot water tank is mainly due to a natural convection flow in the pipe, that the heat loss coefficient of pipes connected to the top of a hot water tank is high, and that a heat trap can reduce the heat loss coefficient significantly. Further, calculations show that the yearly thermal performance of solar domestic hot water systems is strongly reduced if the hot water tank has a thermal bridge located at the top of the tank.
机译:理论上研究了带有和不带有热阱的热水储罐顶部的管道连接所产生的热损失,并将其与类似的实验研究进行了比较。计算流体动力学(CFD)用于理论分析。研究表明,连接到热水箱顶部的理想绝热管的热损失主要是由于管道中的自然对流引起的,连接到热水箱顶部的管的热损失系数为高的集热器可以显着降低热损失系数。此外,计算表明,如果热水箱在水箱顶部有一个热桥,则太阳能家用热水系统的年热性能会大大降低。