摘要

A mathematical description is given for heat- and moisture-transfer process of an air-conditioning unit and the parameters of its dynamic discrete models are identified. The air conditioning unit studied is passive and does not use the more typical compression system or absorption-refrigeration cycle. The purpose of the unit is to produce a microclimate with controlled relative humidity for crop growth chambers. It is very important to control relative humidity values because their variations can strongly influence crop growing conditions. The different system models are identified for the main operating points and the variation of outdoor disturbance is taken into account. These models are parameterized using polynomial functions in order to provide a single structure for the system. It makes it possible to define an input-output model for simulation of the system dynamics
机译:对空调机组的热和湿气传递过程进行了数学描述,并确定了其动态离散模型的参数。所研究的空调机组是被动的,不使用更典型的压缩系统或吸收式制冷循环。该装置的目的是为作物生长室产生具有相对湿度可控的微气候。控制相对湿度值非常重要,因为它们的变化会严重影响农作物的生长条件。针对主要工作点确定了不同的系统模型,并考虑了室外干扰的变化。使用多项式函数对这些模型进行参数化,以便为系统提供单个结构。可以定义用于模拟系统动力学的输入输出模型