In this paper, the voltage and current stress of a delta-connection of three single-phase boost-type unity power factor rectifier modules (/spl Delta/-Rectifier) is analyzed in order to perform a design comparable to a direct three-phase three-level six-switch unity power factor (conventional) rectifier system. The conduction losses of the power semiconductors are calculated using analytical approximations of the average and RMS values of the component currents, the switching losses are taken from previous experimental investigations. Based on this data an overview of the estimated power losses is given for the /spl Delta/-rectifier as well as for the conventional rectifier for 10 kW output power, 800 VDC output and 320 V/400 V/480 V/530 V (RMS, line-to-line) mains voltage. These investigations finally lead to efficiency and component count figures. Furthermore, special attention is paid to the control of the whole three-phase system, including the DC/DC converter output stages of the line-to-line modules of the /spl Delta/-rectifier. Finally, topics of the continuation of the research are identified as, e.g., the realization of a prototype in order to verify the theoretical results experimentally also for unbalanced mains voltage conditions and with nonideal components such as nonlinear input inductors employing iron powder cores and the analysis of a /spl Delta/-rectifier being formed by single-stage SEPIC-type line-to-line modules.
机译:在本文中,分析了三个单相升压型单位功率因数整流器模块(/ spl Delta / -Rectifier)的三角形连接的电压和电流应力,以进行可与直接三相相比的设计三级六开关统一功率因数(常规)整流系统。功率半导体的传导损耗是使用分量电流的平均值和RMS值的解析近似值来计算的,开关损耗取自先前的实验研究。根据此数据,概述了/ spl Delta /整流器以及常规整流器的估计功率损耗,这些功率损耗分别为10 kW输出功率,800 VDC输出和320 V / 400 V / 480 V / 530 V( RMS(线到线)电源电压。这些调查最终得出效率和组件数量的数字。此外,要特别注意整个三相系统的控制,包括/ spl Delta /整流器的线对线模块的DC / DC转换器输出级。最后,将继续研究的主题确定为例如原型的实现,以便在不平衡的市电电压条件下以及具有非理想组件(例如采用铁粉芯的非线性输入电感器)的实验中验证理论结果,并进行分析/ spl Delta /整流器由单级SEPIC型线对线模块组成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号