This paper discusses automatic gain adjustment in fully-digital-controlled shunt active filters. This is the first step in cooperative control of the active filters based on voltage detection for harmonic damping throughout power distribution systems. In general, an optimal control gain is equal to the characteristic impedance of a distribution line. However, it is difficult to know circuit parameters of a real distribution line, that is, feeder connections, shunt capacitors and loads. Therefore, the main purpose of the gain adjustment is to make each active filter damp out harmonic propagation without considering the circuit parameters. Moreover, the gain adjustment can reduce the compensating currents and losses in each active filter. The two active filters with constant or automatic-adjustable gains are experimentally compared. Experiment results verify the effectiveness of the active filter with automatic gain adjustment.
机译:本文讨论了全数字控制并联有源滤波器中的自动增益调整。这是基于电压检测以对整个配电系统进行谐波阻尼的有源滤波器协同控制的第一步。通常,最佳控制增益等于配电线的特征阻抗。但是,很难知道实际配电线路的电路参数,即馈线连接,并联电容器和负载。因此,增益调整的主要目的是使每个有源滤波器抑制谐波传播,而无需考虑电路参数。此外,增益调整可以减少每个有源滤波器中的补偿电流和损耗。实验比较了具有恒定或自动调节增益的两个有源滤波器。实验结果通过自动增益调整验证了有源滤波器的有效性。