The long-term accelerated aging tests in laboratory environment have been conducted on actual rotating coils subjected to combined stresses including electrical, thermal, mechanical vibration and thermal cycling factors under simulated conditions. It is to identify the meaningful diagnostic measures for the assessment of degradation and the identification of aging mechanisms. Experimental techniques for acquisition and analysis of failure data have been investigated. Partial discharge (PD) measurements have been performed using TE571 digital PD analyzer in different aging periods and a combination of statistical and basic parameters has been studied to evaluate the degradation state of stator winding insulation along with destructive measurements. It has been found that the statistical parameters such as the skewness of PD distributions appear to be correlated with the delamination in the epoxy-mica insulation system. The results provide a basis for an on-line interpretation method of stator winding insulation.
机译:在实际环境中,已经对模拟条件下承受电应力,热应力,机械振动和热循环因子等组合应力的实际旋转线圈进行了长期加速老化测试。这是确定有意义的诊断措施,以评估降解和鉴定老化机制。已经研究了用于获取和分析故障数据的实验技术。使用TE571数字PD分析仪在不同的老化周期中进行了局部放电(PD)测量,并研究了统计参数和基本参数的组合以评估定子绕组绝缘的退化状态以及破坏性测量。已经发现,统计参数例如PD分布的偏斜似乎与环氧-云母绝缘系统中的分层相关。研究结果为定子绕组绝缘在线解释方法提供了依据。