We are developing two broadband RF power standards. One is based on 7 mm coaxial line with APC 7 connector for 10 MHz-18 GHz and the other is based on 2.9 mm coaxial line with K connector for 10 MHz-40 GHz. The power measurement principle is calorimetric isothermal control. In these measurements, the effect of excess heating by the adiabatic line becomes important. In the present work, its evaluation method is presented and experimental results are described.
机译:我们正在开发两个宽带射频功率标准。一种基于10 mm-18 GHz的带有APC 7连接器的7毫米同轴线,另一种基于10 MHz-40 GHz的带有K连接器的2.9毫米同轴线。功率测量原理是量热等温控制。在这些测量中,绝热线产生的过多热量的影响变得很重要。在本工作中,提出了其评估方法并描述了实验结果。