首页> 外文会议> >Singlechannel HCN laser interferometer for electron density measurement on the IR-T1 tokamak
【24h】

Singlechannel HCN laser interferometer for electron density measurement on the IR-T1 tokamak

机译:单通道HCN激光干涉仪,用于在IR-T1托卡马克上测量电子密度

获取原文

摘要

Summary form only given. Interferometry os a standard technique for measuring the line integrated electron density of magnetically confined plasma. It is on the basis on the fact that an electromagnetic wave, on its passage through a plasma, experiences a phase change with respect to the reference beam. A single channel far-infrared (FIR) hydrogen cyanide (HCN) laser interferometer was developed to measure plasma electron density on the IR-T1 tokamak. The structure of the single channel FIR laser interferometer is described. The laser source used in the interferometer was a continuous-wave glow discharge HCN laser with a cavity length of 2 m and power output of about 50 mW at 377 /spl mu/m. This system we used from a heterodyne laser interferometer.
机译:摘要表格仅给出。干涉测量OS一种用于测量磁带磁带等离子体线路集成电子密度的标准技术。它是基于:电磁波在其通过等离子体上的通道中,经历相对于参考光束的相位变化。开发了一种通道远红外(FIR)氰化氢(HCN)激光干涉仪以测量IR-T1 TOKAMAK上的等离子体电子密度。描述了单通道FIR激光干涉仪的结构。在干涉仪中使用的激光源是连续波发光放电HCN激光器,腔体长度为2米,功率输出为约50mW,377 / SPL MU / m。该系统从外差激光干涉仪使用。