首页> 外文会议> >Detectability of vehicle exhaust hydrocarbons: the Wisconsin inspection/maintentance (I/M) analyzer and the remote vehicle emissions sensing (RVES) system
【24h】

Detectability of vehicle exhaust hydrocarbons: the Wisconsin inspection/maintentance (I/M) analyzer and the remote vehicle emissions sensing (RVES) system

机译:车辆废气碳氢化合物的可检测性:威斯康星州检查/维护(I / M)分析仪和远程车辆排放物检测(RVES)系统

获取原文

摘要

Abstract: The Wisconsin Departments of Transportation and Natural Resources evaluated the hydrocarbon (HC) detection capability of the Remote Vehicle Emissions Sensing (RVES) system, which employs remote sensing technology, and Wisconsin's I/M analyzers, which use BAR90 specifications. Both analyzers employ non-dispersive infrared (NDIR) technology. Other recent research has quantified HC measurement inaccuracies for vehicle emissions analyzers that use NDIR technology or have BAR90 specifications. This research shows that BAR90 analyzers undermeasure some water- soluble HCs and NDIR analyzers undermeasure olefinic and aromatic HCs. This evaluation was based on both field measurements and calculations that simulate these inaccuracies. These calculations give a measurement accuracy value, which estimates the fraction of the total HCs in a vehicle exhaust sample that each analyzer measures. Other calculations quantify the ozone forming potential of this measured fraction by considering the reactivity of measured HCs. Our field measurements and calculations show Wisconsin I/M analyzer HC measurements are on average 7 percent and 1 percent less than RVES, respectively. Calculations estimate that both analyzers measure at most 43 to 71 percent (an average 61 percent) of the total HCs in an emissions sample. Additional calculations estimate that the HCs measured by both analyzers have 49 to 71 percent (an average 62 percent) of the ozone forming potential of the total HCs in an emissions sample. !16
机译:摘要:威斯康星州运输和自然资源部门评估了采用遥感技术的远程车辆排放物传感(RVES)系统和使用BAR90规格的威斯康星州I / M分析仪的碳氢化合物(HC)检测能力。两种分析仪均采用非分散红外(NDIR)技术。最近的其他研究对使用NDIR技术或BAR90规格的车辆排放分析仪的HC测量误差进行了量化。该研究表明,BAR90分析仪可测量某些水溶性HC,而NDIR分析仪可测量烯烃和芳烃HC。该评估基于现场测量和模拟这些误差的计算。这些计算提供了一个测量精度值,该值可估算每个分析仪测量的车辆废气样品中总HC的分数。其他计算通过考虑被测HCs的反应性来量化该被测馏分的臭氧形成潜力。我们的现场测量和计算表明,威斯康星州I / M分析仪的HC测量值分别比RVES低7%和1%。计算估计,这两个分析仪最多只能测量排放样品中总HC的43%至71%(平均61%)。额外的计算估计,两个分析仪测得的HC占排放样品中总HC的臭氧形成潜能的49%至71%(平均62%)。 !16

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号