Late potentials, which are abnormal high-frequency, low-amplitude signals found near the end of the QRS complex, are known to be an indication of susceptibility to ventricular arrhythmias in certain groups of patients. Signal-averaging, the standard method for detecting late potentials, cannot reliably detect signals which are inconsistent from beat-to-beat. Recent attempts to improve the predictive accuracy of signal-averaging by employing atrial pacing to induce cycle-length dependent effects have reported mixed results, possibly due to beat-to-beat variations in the late potential signal. The author reports preliminary results using time-sequenced adaptive filtering to detect late potentials beat-to-beat at the resting heart rate and during atrial pacing.
机译:晚期电位是在QRS波群末端附近发现的异常高频,低振幅信号,已知是某些患者对室性心律不齐的易感性指标。信号平均是检测迟电势的标准方法,不能可靠地检测逐个拍子不一致的信号。最近通过尝试通过心房起搏来诱导周期长度依赖性效应来改善信号平均的预测准确性的尝试已报告了混合结果,这可能是由于后期电位信号的逐次跳动所致。作者报告了使用时间序列自适应滤波的初步结果,以检测在静息心率和心房起搏期间的逐次心跳后期电位。