首页> 外文会议> >Detection of mitral stenosis by a pulsed Doppler flowmeter and autoregressive spectral analysis method
【24h】

Detection of mitral stenosis by a pulsed Doppler flowmeter and autoregressive spectral analysis method

机译:脉冲多普勒流量计检测二尖瓣狭窄及自回归光谱分析方法

获取原文

摘要

In this study, Doppler signals are recorded from normal patients and patients with mitral stenosis by using a pulsed Doppler unit. The sample volume is located at the ventriculer side of the mitral valve orifice with the aid of an integrated cardiac imaging facility. The analog signal at the output of the Doppler unit is sampled and digitised using an analog/digital interface board and transferred to a personal computer. The data are then analysed using both FFT and AR modeling methods of spectral analysis, and sonograms are obtained. Results show that the AR method offers a superior performance over the FFT method regarding the assessment of mitral stenosis.
机译:在本研究中,通过使用脉冲多普勒单元,从正常患者和二尖瓣狭窄患者记录多普勒信号。样品体积借助于集成的心脏成像设施位于二尖瓣孔的腹腔侧。使用模拟/数字接口板对多普勒单元输出的模拟信号进行采样,并将其传输到个人计算机。然后使用光谱分析的FFT和AR建模方法分析数据,并获得超声图。结果表明,AR方法提供了关于二尖瓣狭窄评估的FFT方法的卓越性能。