Sample aspect ratio influence on the shear coefficients measurements of a piezoelectric bar

机译:样品纵横比对压电棒的剪切系数测量的影响

获取原文

摘要

The variation of the shear related coefficient measurements of a piezoelectric bar with respect to the sample aspect ratio is investigated. This study is carried out with PZT P188 and PZT P189 prismatic rods. The inter-electrodes distance is t and L is the length along the polar axis. Samples with aspect ratio t/L lying between 0.04 and 20 have been characterised using a resonance method. The k/sub 15/ coefficient is then derived with either a constant field model (high t/L) or a constant induction model (small t/L). The dependencies of k/sub 15/, d/sub 15/ and /spl epsiv//sub 11//sup T/ on the aspect ratio are given. The derived d/sub 15/ constants are compared with a direct measurement, made in a quasi-static mode using a Laser Doppler Vibrometry technique, and with ATILA F.E.M. simulations. For low t/L ratios, a clamping of the bar is shown. Moreover, /spl epsiv//sub 11//sup T/ is strongly dependent on the aspect ratio. For high t/L ratios, no clamping is observed and the permittivity is roughly constant. Finally, the use of a constant field model is justified. The best agreement between the different analyses is obtained for t/L ratios higher than 8.
机译:研究了压电棒的剪切相关系数测量值相对于样品纵横比的变化。这项研究是使用PZT P188和PZT P189棱柱棒进行的。电极间距离为t,L为沿极轴的长度。使用共振方法对长宽比t / L在0.04至20之间的样品进行了表征。然后使用恒定场模型(高t / L)或恒定感应模型(小t / L)导出k / sub 15 /系数。给出了k / sub 15 /,d / sub 15 /和/ spl epsiv // sub 11 // sup T /对纵横比的依赖性。将导出的d / sub 15 /常数与使用激光多普勒振动计技术以准静态模式以及ATILA F.E.M.进行的直接测量进行比较。模拟。对于低的t / L比率,显示了棒的夹紧。此外,/ spl epsiv // sub 11 // sup T /很大程度上取决于纵横比。对于高的t / L比,没有观察到钳位并且介电常数大致恒定。最后,使用恒定场模型是合理的。 t / L比率高于8时,将获得不同分析之间的最佳一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号