首页> 外文会议> >A method for interlaboratory stripline susceptibility test calibration
【24h】

A method for interlaboratory stripline susceptibility test calibration

机译:实验室间带状线药敏试验校准的方法

获取原文

摘要

A method is presented for correlating susceptibility tests between two different electromagnetic compatibility (EMC) laboratories using stripline antenna test methods by utilizing similar test antennas. A controlled test antenna is used along with swept frequency techniques to gather data rapidly which are then used to correlate results from two or more laboratories or to locate and eliminate the causes of variation between laboratories. If differences in the two sets of measurements cannot be eliminated, these results can be used to provide a quantitative prediction of the differences between the test results to be expected between the two laboratories. The advantage of this approach is that the device under test in this case is passive, uniform, and easily duplicated in different laboratories and does not have many of the disadvantages associated with transporting a generic active device under test from one laboratory to another. The method can be used as a periodic check on the performance of the test system since each laboratory can easily possess its own standard antenna.
机译:提出了一种使用带状线天线测试方法,通过利用相似的测试天线,使两个不同的电磁兼容性(EMC)实验室之间的磁化率测试相关的方法。受控的测试天线与扫频技术一起使用,可以快速收集数据,然后将其用于关联来自两个或多个实验室的结果,或查找并消除实验室之间差异的原因。如果无法消除两组测量值之间的差异,则可以使用这些结果对两个实验室之间预期的测试结果之间的差异进行定量预测。这种方法的优势在于,在这种情况下,被测设备是被动的,统一的,并且易于在不同的实验室中复制,并且没有与将通用的被测有源设备从一个实验室运送到另一个实验室相关的许多缺点。该方法可以用作对测试系统性能的定期检查,因为每个实验室都可以轻松拥有自己的标准天线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号