Recently, Telecom Australia has pioneered practical cost-effective methods for using the relatively high latent heat of fusion of phase-change chemicals (PCC) to provide thermal storage reserve cooling and conservation of energy in the building environment. The authors identify and outline performance characteristics of currently used PCC systems. They also introduce a novel passive building-cooling system for special high-reliability applications in remote-area communication sites. Such a low-cost minimum-maintenance system combines a thermally transparent equipment room that will maintain equipment within satisfactory environmental limits for most of the year with a special PCC thermal storage unit to give additional reserve cooling on hot days. The cool PCC storage may be provided through either a small air-conditioner or a fresh-air cycle during times of cooler weather. Mention is made of PCCs that are currently available in Australia and their suitability for application in PCC systems. PCC systems that are successfully being used by Telecom as well as exploratory PCC systems that are being investigated are briefly reviewed.
机译:最近,澳大利亚电信公司率先开创了实用的,具有成本效益的方法,可以使用相变化学物质(PCC)的相对较高的潜热融合来在建筑环境中提供蓄热储备冷却和能源节约。作者确定并概述了当前使用的PCC系统的性能特征。他们还介绍了一种新颖的被动式建筑物冷却系统,用于偏远地区通信站点的特殊高可靠性应用。这种低成本的最低维护系统将透明的机房与特殊的PCC蓄热单元相结合,该机房可在一年中的大部分时间内将设备保持在令人满意的环境范围内,以在炎热的天气提供额外的备用冷却。在天气凉爽时,可以通过小型空调或新鲜空气循环来提供凉爽的PCC存储。提到了目前在澳大利亚可用的PCC及其在PCC系统中的适用性。简要回顾了电信成功使用的PCC系统以及正在研究的探索性PCC系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号