首页> 外文会议> >A study of brachial plexus potentials using a 3-dimensional electrode array
【24h】

A study of brachial plexus potentials using a 3-dimensional electrode array

机译:利用三维电极阵列研究臂丛神经电位

获取原文

摘要

Brachial plexus potentials were investigated with a three-dimensional orthogonal electrode array. The array was simulated using an ideal, infinitely homogeneous model. The model was verified by testing human subjects with the arm abducted at three different angles to determine whether changes in nerve orientation would alter the potential waveforms. Potentials were recorded for both ulnar and median nerves. Results show qualitative correlation between the simulation and test results. Differences between the median and ulnar nerve waveforms were consistently measurable, and the change in shoulder position was shown to the statistically correlated with changes in waveform latencies. The results suggest that observed differences and changes are due to the change in dipole orientation rather than the change in current density that occurs when the nerve enters the torso from the arm.
机译:用三维正交电极阵列研究臂丛神经电位。使用理想的无限均质模型对阵列进行了仿真。通过测试人类受试者的手臂在三个不同的角度绑架,以确定神经方向的变化是否会改变电位波形,从而验证了该模型。记录尺神经和正中神经的电位。结果显示了仿真结果与测试结果之间的质量相关性。正中和尺神经波形之间的差异可始终测量,并且肩部位置的变化与波形潜伏期的变化在统计学上相关。结果表明,观察到的差异和变化是由于偶极子方向的变化,而不是神经从手臂进入躯干时发生的电流密度的变化。