首页> 外文会议>Measurement of Atmospheric Gases >VUV/photofragmentation laser-induced fluorescence sensor for the measurement of atmospheric ammonia
【24h】

VUV/photofragmentation laser-induced fluorescence sensor for the measurement of atmospheric ammonia

机译:VUV /光碎裂激光诱导的荧光传感器,用于测量大气中的氨

获取原文
获取原文并翻译 | 示例

摘要

Abstract: Vacuum-ultraviolet/photofragmentation-laser-induced fluorescence (VUV/PF-LIF) has been demonstrated to be a highly specific and sensitive method for the quantitative measurement of atmospheric ammonia (NH$- 3$/). The fluorescence detected in this approach results from the two photon (193 nm) photofragmentation of NH$-3$/ followed by the LIF excitation of the NH(b$+1$/$SUM$+$PLU$/) $YLD NH(c$+1$/II) (at 452 nm) and the monitoring of fluorescence from the NH(c$+1$/II) $YLD NH(a$+1$/$Delta@) transition at 325 nm. Limits of detection for the instrument presented here are $LS 10 pptv and $LS 4 pptv for one and five minute integration periods, respectively, under ambient sampling conditions. The technique is free from interferences and system performance does not significantly degrade under adverse sampling conditions (i.e. rain, fog, clouds, haze, etc.). Spectroscopic selectivity in the NH(b$+1$/$SUM$+$PLU$/) $YLD NH(c$+1$/II) transition is sufficient to resolve $+15$/NH$-3$/ and $+14$/NH$-3$/ contributions for use in atmospheric tracer studies. Average ammonia measurements at Stone Mtn., GA, range from $APEQ 110 pptv for air temperatures $LS 5$DGR@C to $APEQ 240 pptv for air temperatures $GREQ 5$DGR@C over the period from December 1987 to the end of April 1988. Ammonia levels measured at Green Mountain Mesa, Boulder CO, ranged from 10 pptv to 10 ppbv for measurements made during March 1989. Ammonia levels were seen to vary from about 300 pptv to greater than 5 ppbv over time scales of $LS 10 minutes in this latter data set. These results and future instrument improvements are discussed.!
机译:摘要:真空紫外/光碎裂激光诱导的荧光(VUV / PF-LIF)已被证明是定量测定大气中氨(NH $ -3 $ /)的高度特异性和灵敏方法。在这种方法中检测到的荧光是由NH $ -3 $ /的两个光子(193 nm)光碎裂和随后的NH(b $ + 1 $ / $ SUM $ + $ PLU $ /)$ YLD NH的LIF激发引起的(c $ + 1 $ / II)(在452 nm处)和在325 nm处监测NH(c $ + 1 $ / II)$ YLD NH(a $ + 1 $ / $ Delta @)跃迁的荧光。此处介绍的仪器在环境采样条件下,在一分钟和五分钟积分期间的检出限分别为$ LS 10 pptv和$ LS 4 pptv。该技术不受干扰,在不利的采样条件下(即雨,雾,云,雾霾等),系统性能也不会显着降低。在NH(b $ + 1 $ / $ SUM $ + $ PLU $ /)$ YLD NH(c $ + 1 $ / II)转换中的光谱选择性足以解决$ + 15 $ / NH $ -3 $ /和$ + 14 $ / NH $ -3 $ /供大气示踪研究使用。在1987年12月至年底期间,佐治亚州斯通山的平均氨气测量值从$ PEPQ 110 pptv的空气温度$ LS 5 $ DGR @ C到$ APEQ 240 pptv的空气温度$ GREQ 5 $ DGR @ C 1988年4月的数据。在1989年3月进行的测量中,在Boulder CO的Green Mountain Mesa测得的氨水平范围从10 pptv到10 ppbv。在$ LS的时间范围内,氨水平从300 pptv到大于5 ppbv不等。后一个数据集中的10分钟。讨论了这些结果和将来的仪器改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号