LONG-TERM MEASUREMENT OF MOLECULAR CONTAMINATION IN A CLEANROOM USING A TEMPERATURE-CONTROLLED QUARTZ CRYSTAL MICROBALANCE (TQCM)

机译:使用温度控制的石英晶体微平衡(TQCM)长期测量洁净室中的分子污染

获取原文
获取原文并翻译 | 示例

摘要

TQCMs have been operated in the Spacecraft System Development and Integration Facilityrn(SSDIF) cleanroom at Goddard Space Flight Center (GSFC) since 1993 to provide a measure ofrnmolecular contamination. This has resulted in long term data that gives an indication of the rate ofrnmolecular contamination deposited on a surface (such as an optical mirror) and gives an indication ofrnfacility cleanliness. Long term trends in contamination deposition and facility cleanliness can berndetected by this method.rnOne TQCM has been operated at room temperature in the same location within the cleanroomrnwith the same controller, test cables, and computer for over six years. The cleanroom has beenrnmaintained at essentially the same temperature and relative humidity during this period. A secondrnTQCM has been operated at different locations within the cleanroom with different cables, but duringrnperiods of constant operation it has shown a similar rate of accumulation.rnData collected over the six year period shows an average increase of about 30 Hz per year for 15rnMHz TQCMs with a sensitivity of 1.56 x 10~(-9) gms/cm~2/Hz. This equates to a mass accumulation ofrn0.047 x 10~(-6) gms/cm~2 per year which is about one 20th of that allowed for MIL STD 1246 Level A (1.0 xrn10~(-6) gms/cm~2). The accumulation rate has been relatively constant over the six years.rnAnalysis of the contamination deposited on the TQCM surface was performed using FTIRrn(Fourier Transform Infrared Spectroscopy) and GC/MS (Gas Chromatography/Mass Spectroscopy). Thernresults show typical cleanroom molecular contaminants detected over the years by other means (witnessrnmirrors and collection plates).
机译:自1993年以来,TQCM已在戈达德太空飞行中心(GSFC)的航天器系统开发和集成设施(SSDIF)洁净室中运行,以提供一定程度的分子污染。这产生了长期数据,该数据给出了沉积在表面(如光学镜)上的分子污染的速率的指示,并给出了设备清洁度的指示。通过这种方法可以检测出污染物沉积和设备清洁度的长期趋势。一个TQCM在室温下在洁净室中的同一位置使用相同的控制器,测试电缆和计算机运行了超过六年。在此期间,洁净室基本上保持在相同的温度和相对湿度下。第二个TQCM已在洁净室中的不同位置使用不同的电缆进行了操作,但是在持续运行期间,它显示出相似的累积速率。六年期间收集的数据表明,对于15rnMHz TQCM,每年平均增加约30 Hz灵敏度为1.56 x 10〜(-9)gms / cm〜2 / Hz。这相当于每年的质量积累为rn0.047 x 10〜(-6)gms / cm〜2,约为MIL STD 1246 A级允许的质量积累(1.0 xrn10〜(-6)gms / cm〜2 )。在过去的六年中,累积速率一直相对稳定。使用FTIRrn(傅里叶变换红外光谱)和GC / MS(气相色谱/质谱)对TQCM表面沉积的污染物进行分析。结果表明,多年来通过其他方法(见证镜和收集板)检测到典型的洁净室分子污染物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号