Laboratory evaluations of a 25-mm drill bit isolator to reduce noise from roof bolting machines in underground coal mines

机译:25毫米钻头隔离器的实验室评估,以减少地下煤矿的顶锚机产生的噪声

获取原文

摘要

Roof bolting machine noise is a significant health hazard in underground coal mining because the sound levels at the operator station often exceed 100 dB(A). Drilling the hole prior to installing the roof bolt is the most significant source of operator exposure. The drill steel is the dominant noise source during this operation. NIOSH has developed a noise control to mitigate this exposure. The drill bit isolator is designed to fit in line with the drill bit and drill steel. It is made of two steel cylinders with an elastomer material between them, designed to damp the vibrations of the drill steel as it drills a bolt hole. This noise control is currently commercially available for drilling with 35-mm drill steels. A smaller version, used with 25-mm drill steels, has been laboratory tested at OMSHR facilities and shows a reduction of 2-4 dB at the operator position when drilling in granite. The evolution of the device as well as laboratory evaluations are described in this paper. Field evaluations are underway and final steps are being taken to bring the 25-mm drill bit isolator to fruition as a commercially available noise control.
机译:顶板锚固机噪声在地下煤矿开采中是严重的健康危害,因为操作员站的声级通常超过100 dB(A)。在安装顶棚螺栓之前先钻孔,这是操作员暴露的最重要原因。在此操作期间,钻钢是主要的噪声源。 NIOSH开发了一种噪音控制来减轻这种暴露。钻头隔离器设计为与钻头和钻钢对齐。它由两个带有弹性体材料的钢制圆柱体制成,旨在阻尼钻钢在钻入螺栓孔时的振动。目前,这种噪声控制在商业上可用于35毫米钻钢的钻孔。较小的版本,用于25毫米钻钢,已经在OMSHR设施中进行了实验室测试,显示出在花岗岩上钻孔时,操作员位置减小了2-4 dB。本文介绍了该设备的发展以及实验室评估。目前正在进行现场评估,并已采取最后步骤将25毫米钻头隔离器作为一种可商购的噪声控制产品来加以实现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号