Failures in the tensile armour wires of flexible risers can be detectedthrough the reduction in applied stress in failed wires. Further thefailure can be detected many metres from the point of failure and evenwithin the end fitting because of the unbonded nature of the flexibleriser. A magnetic system for measuring and comparing the stress in allthe tensile armour wires around the circumference of a riser has beenbuilt and tested. The system successfully detected wire failures causedby cyclic fatigue in a full size riser undergoing fatigue test.
机译:可以通过减少失效钢丝中施加的应力来检测柔性立管的拉伸铠装钢丝的失效。此外,由于柔性冒口的无粘结特性,可以从故障点甚至在末端配件内数米处检测到故障。已经建立并测试了用于测量和比较立管周围所有拉伸铠装线中应力的磁性系统。该系统成功地检测了正在经受疲劳测试的全尺寸立管中由周期性疲劳引起的电线故障。