Effect Produced on Electromagnetic Leakage in PLC by Indoor Power line Arrangements

机译:室内电源线布置对PLC电磁泄漏产生的影响

获取原文
获取原文并翻译 | 示例

摘要

The effect of electric field strength leakage produced when short wave band PLC is impressed on indoor power lines is mainly dependent on the balance of indoor power lines. When the present balance sample values of indoor power lines, collected in Europe, America and Japan are observed, as far as average values are seen, the values are not bad compared with those of communication lines but there are cases where locally, the balance becomes extremely bad and the electric field strength which leaks from such parts becomes large. However with PLC that uses short wave bands from 1 MHz to 30 MHz, its resonance wavelength is longer than those of indoor power lines and therefore the electric field strength leakage differs from the energy sum of the local electromagnetic wave leakage. By making a model house by deeming the entire house a short wave antenna, it is believed that the electric field strength leakage produced by impressing a short wave band PLC signal on a detached house can be estimated but the wiring form of indoor power lines is extremely complicated and since the form, number of branches, wiring method differ by house, it is difficult to make a house a model. Therefore, in this paper, with the object of gathering basic data to estimate the leaked electric field strength when a short wave PLC is introduced to a general detached house, measurements were taken of the changes in electric field strength leakage by short wave band PLC signals with changes in balance resulting from various simple indoor power lines.
机译:在室内电力线上施加短波PLC时产生的电场强度泄漏的影响主要取决于室内电力线的平衡。观察欧洲,美洲和日本收集的室内电力线的当前平衡采样值,就平均值而言,该值与通信线相比并不差,但在局部情况下,平衡变为极差,从这些部分泄漏的电场强度变大。但是,对于使用从1 MHz到30 MHz的短波段的PLC,其谐振波长比室内电力线的谐振波长长,因此电场强度泄漏与局部电磁波泄漏的能量总和不同。通过将整个房屋视为短波天线来制作样板房,可以相信,通过将短波带PLC信号施加在独立式房屋上而产生的电场强度泄漏可以估计出来,但是室内电源线的布线形式却极为复杂。由于房屋的形式,分支的数量,布线方法的复杂,并且房屋难以建模。因此,在本文中,以收集短波PLC引入普通独立式住宅时泄漏电场强度的基本数据为目的,对短波PLC信号对电场强度泄漏的变化进行了测量。各种简单的室内电源线导致的平衡变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号