This paper presents an investigation into the effects of tinier jitter on the accuracy of measured results when using a digital signal processor card in a PC based measurement system. These results are particularly applicable for drive system engineers. Jitter is the error between the ideal sampling period and the actual sampling period. Timer jitter has different effects on the accuracy of the measured output depending upon the type of signal to be measured. Current sampling frequencies (10-20kHz) of typical DSP systems are too low for the measurement of PWM waveforms in power applications. Timer error means that pulses that are small in width may be missed when sampled, even if the measurement system is synchronized with the PWM generation. The resulting sampled data misrepresents the actual waveform. However, the error as a result of timer jitter in the measured data is negligible when sampling sinusoidal or slow changing waveforms. Experimental results are presented to show the effect of timer error. Timer jitter was measured and found to be as high as +/-10% for a stated sampling period of 50 μs for the DSP card being used. Tinier jitter had a negligible effect on the sampled data when the signal was a near sinusoidal waveform. Spectral analysis was also undertaken to highlight the results. Computer simulated results confirmed the errors produced by timer jitter.
机译:本文介绍了在基于PC的测量系统中使用数字信号处理器卡时,微小抖动对测量结果准确性的影响。这些结果特别适用于驱动系统工程师。抖动是理想采样周期与实际采​​样周期之间的误差。定时器抖动对被测输出的精度有不同的影响,具体取决于被测信号的类型。典型的DSP系统的电流采样频率(10-20kHz)太低,无法测量电源应用中的PWM波形。定时器错误意味着即使在测量系统与PWM生成同步的情况下,采样时也会丢失宽度较小的脉冲。最终的采样数据代表了实际的波形。但是,当采样正弦波形或缓慢变化的波形时,由于测量数据中的计时器抖动而导致的误差可以忽略不计。实验结果表明定时器错误的影响。对定时器抖动进行了测量,发现在规定的50μs采样周期内,所使用的DSP卡的抖动高达+/- 10%。当信号接近正弦波形时,微小的抖动对采样数据的影响可以忽略不计。还进行了光谱分析以突出结果。计算机仿真结果证实了计时器抖动产生的错误。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号