This paper is concerned with the measurement of short-circuit loop impedance in electrical low voltage network with operating loads. The paper discusses and analyzes the influence of the operating network load on the accuracy of loop impedance measurement when are use classical instruments and methods. The results of analysis indicate that the effect of the operating load is significant especially when the measurement point is close to the induction motors. The paper presents the new vectorial method for measurement loop impedance in which the influence of operating loads on measurement result is eliminated. The relations are derived for determining the values of magnitude loop impedance Z and its orthogonal component resistance R and reactance X.
机译:本文涉及带有工作负载的低压电网中短路回路阻抗的测量。本文讨论并分析了使用传统仪器和方法时,工作网络负载对环路阻抗测量精度的影响。分析结果表明,特别是当测量点靠近感应电动机时,工作负载的影响尤其明显。本文提出了一种用于测量环路阻抗的矢量方法,该方法消除了工作负载对测量结果的影响。推导这些关系以确定幅值环路阻抗Z的值及其正交分量电阻R和电抗X.