USE OF HEAT PIPES TO IMPROVE TEMPERATURE PERFORMANCE OF A CHILLED REFRIGERATED DISPLAY CABINET

机译:使用热管来提高冷冻冷藏显示柜的温度性能

获取原文
获取原文并翻译 | 示例

摘要

A heat pipe was used to provide cooling to the front of the shelf of a glass door refrigerated display cabinet.rnThe heat pipe reduced the core temperature of the test pack above it by 0.2 K. A thermal imaging camerarnwas used to ascertain boundary conditions for a CFD model which then predicted a reduction in the corerntemperature of the test pack above the heat pipe by 0.5 K The reason for the limited benefit of the heat pipernmeasured and predicted was that the temperature of the shelf below the front pack was only slightly higherrnthan the heat pipe cooling it. Using the thermal imaging camera and the CFD model, the predictions werernextended to an open fronted cabinet. The heat pipe was predicted to reduce the core temperature of the testrnpack above it by 1.7 K Heat pipes were shown to be of more benefit in open fronted than glass doorrncabinets.
机译:使用热管为玻璃门冷藏展示柜的架子的前部提供冷却。rn热管将测试包上方的测试包的核心温度降低了0.2K。使用热成像摄像机rn确定了温度的边界条件。 CFD模型随后预测了热管上方的测试包的中心温度降低了0.5K。测量和预测的热管益处有限的原因是,前包下方的架子温度仅比热量略高用管道冷却它。使用红外热像仪和CFD模型,将预测结果扩展到一个开放式的柜子中。据预测,热管将比其上方的测试包的核心温度降低1.7K。与开门式柜相比,热管在敞开式正面显示出更多的优势。

著录项

  • 来源
  • 会议地点 London(FR)
  • 作者

    A Foster; M Orlandi; J Evans;

  • 作者单位

    London South Bank University, UK, +44 117 9289281, alan.foster@lsbu.ac.uk;

    Epta S.p.a., Milano, Italy;

    London South Bank University, UK;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号