首页> 外文OA文献 >Use of heat pipes to improve temperature performance of a chilled refrigerated display cabinet
【2h】

Use of heat pipes to improve temperature performance of a chilled refrigerated display cabinet

机译:使用热管来改善冷藏冷藏展示柜的温度性能

摘要

A heat pipe was used to provide cooling to the front of the shelf of a glass door refrigerated display cabinet. The heat pipe reduced the core temperature of the test pack above it by 0.2 K. A thermal imaging camera was used to ascertain boundary conditions for a CFD model which then predicted a reduction in the core temperature of the test pack above the heat pipe by 0.5 K The reason for the limited benefit of the heat pipe measured and predicted was that the temperature of the shelf below the front pack was only slightly higher than the heat pipe cooling it. Using the thermal imaging camera and the CFD model, the predictions were extended to an open fronted cabinet. The heat pipe was predicted to reduce the core temperature of the test pack above it by 1.7 K Heat pipes were shown to be of more benefit in open fronted than glass door cabinets.
机译:使用热管为玻璃门冷藏展示柜的架子的前端提供冷却。热管将其上方的测试包的核心温度降低了0.2K。使用热像仪确定CFD模型的边界条件,然后预测CFD模型的边界条件,热管上方的测试包的核心温度将降低0.5 K测量和预测的热管的好处有限的原因是,前包装下面的架子温度仅略高于冷却前架子的温度。使用热像仪和CFD模型,将预测结果扩展到开放式橱柜中。预计热管会将其上方的测试包的中心温度降低1.7 K,与开门玻璃柜相比,热管在敞开式正面显示出更多的优势。

著录项

  • 作者

    Foster A; Orlandi M; Evans J;

  • 作者单位
  • 年度 2014
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利