STUDY ON OPTIMAL SHEAR WALL QUANTITY OF FRAME-SHEAR WALL STRUCTURES IN EARTHQUAKE ZONE

机译:地震区框架-剪力墙结构的最佳剪力墙数量研究

获取原文
获取原文并翻译 | 示例

摘要

The method for figuring the optimal shear wall quantity for frame-shear wall tall buildings with variable lateral rigidity along the height in earthquake zone is presented in this paper by means of dispersal-serial interaction method. It is the first time to put forward the method for figuring the optimal amount of shear wall in frame-shear wall structure by classifying the vertical members. The definition of Inter-Story Drift is made clear and definite by the author. A 20-storey framed-shear wall tall building is numerically examined and the results show that the method is accurate enough for use in the preliminary stage of design.
机译:提出了一种利用离散-串行相互作用法求出沿地震高度高度变化而具有侧向刚度的框架剪力墙高层建筑的最佳剪力墙的方法。首次提出了通过对竖向构件进行分类来确定框架剪力墙结构中剪力墙最佳量的方法。作者对层间漂移的定义进行了明确和明确的定义。对20层框架剪力墙高层建筑进行了数值检查,结果表明该方法足够准确,可用于设计的初期阶段。