摘要

Jinan Power Supply Company has already built a complete distribution automation system and realized some basic functions. However the detection (including positioning and wire selection) of small current neutral grounding fault remains unsolved up till now. This paper elaborates the development and application of this system. Through the determination of distribution network fault and intensive study of isolation principle, on the basis of the existing distribution network, the software and hardware have undergone necessary upgrading and transformation so that the functions such as the automatic positioning of small current neutral grounding fault, isolation and restoring power supply for the whole section to guarantee stability, security and economical operation on the part of Jinan power distribution network.
机译:济南供电公司已经建立了完整的配电自动化系统,并实现了一些基本功能。但是,到目前为止,小电流中性点接地故障的检测(包括定位和选线)仍未解决。本文阐述了该系统的开发和应用。通过确定配电网故障并深入研究隔离原理,在现有配电网的基础上,对软件和硬件进行了必要的升级改造,从而实现了小电流中性点接地故障的自动定位,隔离等功能。整段供电,保证济南配电网的稳定,安全和经济运行。