首页> 外文期刊>International journal of electrical power and energy systems >Zero-sequence compensated admittance based faulty feeder selection algorithm used for distribution network with neutral grounding through Peterson-coil
【24h】

Zero-sequence compensated admittance based faulty feeder selection algorithm used for distribution network with neutral grounding through Peterson-coil

机译:基于零序补偿导纳的故障馈线选择算法,用于通过彼得森线圈进行中性点接地的配电网

获取原文
获取原文并翻译 | 示例
           

摘要

For faulty feeder selection problem in case of single-phase grounding fault in distribution network with neutral point un-effectively grounded, a novel per-unit zero-sequence compensated admittance based faulty feeder selection algorithm was proposed. By introducing the compensated admittance, the difference of zero sequence admittance between the faulty feeder and the sound feeders was amplified, which could be utilized as a technically practical judging criterion. In order to eliminate the discrimination dead zone, the ratio of compensated admittance with respect to the susceptance of the feeder itself is adopted as supplement criterion. Together with the admittance angle criterion, a reliable comprehensive criterion for identifying single-phase grounding fault feeder in neutral point non-effectively grounded system is formed. A series of simulation test results indicate that, the algorithm proposed is independent of the network structure and parameters, the fault condition or the fault resistance, thus improving the success rate of fault feeder selection significantly.
机译:针对中性点未有效接地的配电网单相接地故障的故障馈线选择问题,提出了一种基于零序零序补偿导纳的故障馈线选择算法。通过引入补偿导纳,放大了故障馈线与声音馈线之间零序导纳的差,可作为技术上的实用判据。为了消除辨别盲区,采用补偿导纳相对于馈线本身电纳的比率作为补充标准。结合导纳角判据,形成了用于中性点非有效接地系统单相接地故障馈线识别的可靠综合判据。一系列的仿真测试结果表明,所提算法与网络结构和参数,故障条件或故障电阻无关,从而显着提高了故障馈线选择的成功率。

著录项

  • 来源
  • 作者单位

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology (HUST), Wuhan 430074, PR China;

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology (HUST), Wuhan 430074, PR China;

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology (HUST), Wuhan 430074, PR China;

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology (HUST), Wuhan 430074, PR China;

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology (HUST), Wuhan 430074, PR China;

    College of Electrical Engineering and Information Technology, Three Gorges University, Yichang 443002, Hubei Province, PR China;

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology (HUST), Wuhan 430074, PR China,School of Electrical & Electronic Engineering (Xi Jiu Lou), Huazhong University of Science and Technology, Luoyu Road 1037, Wuhan 430074, Hubei, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Neutral un-effectively grounded system; Single phase-to-earth fault; Zero sequence compensated admittance;

    机译:中性点无效接地系统;单相接地故障;零序补偿导纳;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号