首页> 外文会议>International conference on electrical machines and systems (ICEMS2007) >Calculation of the Circulating Current and Short-Circuit Impedance of a 3000kVA HTS Transformer with Split Types of Windings
【24h】

Calculation of the Circulating Current and Short-Circuit Impedance of a 3000kVA HTS Transformer with Split Types of Windings

机译:绕组分体式3000kVA HTS变压器的环流和短路阻抗的计算

获取原文

摘要

A conceptual design of a 3000kVA high-temperature superconducting (HTS) transformer with split types of windings for locomotives is developed in this paper. The primary winding of it has four coils which are arranged on two core limbs respectively and connected in parallel, so the branch currents are probably not equal to each other. In this paper, on the basis of the 3-D magnetic field analysis by finite element method (FEM), an inductance matrix (IM) for multi-branch of the primary winding and one of the secondary split windings is first calculated, and then the circulating current among the primary branches is determined by circuit theory. Finally, the short-circuit impedance between the primary winding and one of the secondary split windings is obtained.
机译:本文开发了一种3000kVA高温超导(HTS)变压器,该变压器具有机车绕组的分体类型。它的初级绕组有四个线圈,分别布置在两个铁心柱上并并联连接,因此分支电流可能彼此不相等。本文在基于有限元方法(FEM)的3-D磁场分析的基础上,首先计算了一次绕组和一个二次分裂绕组的多分支的电感矩阵(IM),然后初级分支之间的循环电流由电路理论确定。最后,获得了初级绕组和次级分裂绕组之一之间的短路阻抗。

著录项