【24h】

Analysis on Cause of Abnormal Measurement of Seepage of a Dam

机译:大坝渗流测量异常的原因分析

获取原文

摘要

In order to measure seepage of a large reservoir, Geokon 4675LV type weir-above water lever meter is embedded. Measurement of seepage in April, 2007 was changed sudden-ly, afterwards variation magnitude of measurement became less, and it shows a certain rela-tionship with water level of reservoir. In order to investigate the reason that causes the ab-normal measurement of seepage of dam, firstly the paper makes analysis on measurement in-formation of seepage's pressure of related section, and makes manual comparison on meas-urement; furthermore, on this base, it makes a local inspection on weir-above water level meter and corresponding communication cables. The result of which shows that abnormal measurement of seepage of dam is caused by loosened communication cable of weir-above wa-ter level meter. This reason is rather popular for weir-above water level meter during its in-stallation and embedding process.
机译:为了测量大型水库的渗流,内置了Geokon 4675LV型堰式水位计。 2007年4月的渗流测量值突然改变,此后测量值的变化幅度变小,并且显示出与水库水位的一定关系。为了调查导致大坝渗流测量值不正常的原因,本文首先对相关断面渗流压力的测量信息进行分析,并进行手工比较。此外,在此基础上,还要对堰上水位计和相应的通讯电缆进行本地检查。结果表明,堰式水位计通信电缆松动是引起坝体渗流异常的原因。对于堰式水位计在安装和嵌入过程中,此原因颇为流行。