摘要

Thermosiphon elevation solution tube (TEST) is one of important parts of an absorption chiller. Its property determines the efficiency of the absorption refrigeration system. In this paper, several thermosiphon solution elevation tubes with lunate channel are specially designed and constructed. The solution heating and elevating performances of the tubes are measured. The results indicate that the elevated solution volume and distilled water yield increase with the driving temperature and solution submergence. With the suitable section area of the tubes, the net elevating height of solution is 1.9 times as high as the solution submergence, and the lunate channel tubes have several outstanding characteristics, such as low starting temperature (minimum 68℃), wide operating temperature range (68 ~90℃) and lower requirement for vacuum condition(under 10kPa). This shows that elevating capability of lunate elevating tubes is much better than others currently, and it provides well foundation for practical applications.
机译:热虹吸高程溶液管(TEST)是吸收式制冷机的重要组成部分之一。它的性质决定了吸收式制冷系统的效率。本文专门设计和制造了几种带有发光通道的热虹吸溶液提升管。测量管的溶液加热和提升性能。结果表明,升高的溶液体积和蒸馏水产率随驱动温度和溶液浸没而增加。在合适的管子截面积的情况下,溶液的净高程是溶液浸没的1.9倍,并且发光通道管具有一些突出的特性,例如起始温度低(最低68℃),工作温度范围宽。 (68〜90℃)和较低的真空条件要求(10kPa以下)。这表明,月牙举升管的举升能力比目前的举升管要好得多,并且为实际应用提供了良好的基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号