【24h】

PRESSURE DROP AND HEAT TRANSFER CHARACTERISTICS OF SINGLE-PHASE FLOW IN CORRUGATED TUBES FOR HOT-WATER SUPPLY SYSTEMS

机译:供热系统波纹管内单相流的压降和传热特性

获取原文

摘要

In this study, the pressure drop and heat transfer characteristics of single-phase flow in a smooth tube, a helical-grooved tube, and 12 corrugated tubes with an outer diameter of 12.7 mm were experimentally investigated, employing water as test fluid. Geometrical parameters considered for the corrugated tubes were corrugation depth (0.3, 0.5, and 0.9 mm) and corrugation pitch (4, 6, 8, 12, 15, 20, and 25 mm). Experiments were conducted by maintaining the inlet water temperature at 20℃ and varying the flow rate from 0.005 to 0.18 kg/s. The effects of the difference in corrugation pitch and depth on the pressure drop and heat transfer characteristics of single-phase flow in the corrugated tubes were reported. Furthermore, the measured Nusselt numbers of each tested tube were compared under the same conditions of pumping power and a comprehensive evaluation method for heat transfer tubes was described.
机译:在这项研究中,以水为测试液,对光滑管,螺旋槽管和外径为12.7 mm的12根波纹管中的单相流的压降和传热特性进行了实验研究。波纹管考虑的几何参数是波纹深度(0.3、0.5和0.9毫米)和波纹间距(4、6、8、12、15、20和25毫米)。通过将进水温度保持在20℃并将流量从0.005更改为0.18 kg / s进行实验。报道了波纹节距和深度的差异对波纹管中单相流的压降和传热特性的影响。此外,在相同的泵浦功率条件下,比较了每个被测管的实测努塞尔数,并描述了传热管的综合评估方法。