首页> 外文会议>International Conference on Internet of Things: Smart Innovation and Usages >Comparative Study for Steady-State Operation of IAG in Stand-Alone mode using MATLAB and Typhoon HIL
【24h】

Comparative Study for Steady-State Operation of IAG in Stand-Alone mode using MATLAB and Typhoon HIL

机译:使用MATLAB和台风HIL在独立模式下IAG稳态运行的比较研究

获取原文

摘要

A strong platform to understand steady-state analysis and operation of Isolated Asynchronous Generators using a highly advanced FPGA based Typhoon HIL 402 based emulator and its comparison with Matlab Simulink environment is shown. The advantages of real-time simulators are very well explained with its offline models used in MATLAB. The proposed 7.5 Kw, 415 V IAG is excited using a delta connected Capacitor banks and the simulation is carried out in MATLAB SIMULINK and Typhoon HIL at rated loaded conditions to get output voltage of 415 V, 50 Hz.
机译:展示了一个强大的平台,可以使用基于FPGA的高度先进的基于Typhoon HIL 402的仿真器了解隔离式异步发电机的稳态分析和操作,并将其与Matlab Simulink环境进行比较。实时仿真器的优势通过MATLAB中使用的离线模型得到了很好的解释。拟议的7.5 Kw,415 V IAG使用三角形连接的电容器组进行励磁,并且在MATLAB SIMULINK和Typhoon HIL中在额定负载条件下进行了仿真,以获得415 V,50 Hz的输出电压。