A soft-measurement method for gas/water mass flow-rate was brought forward, in which the V-cone differential pressure meter was used and the adaptive wavelet network was developed to achieve the soft-measurement of the mass flow-rate. The multi-input single output model was adopted to approximate the mass flow-rate of gas/liquid. The paper focused on the experimental measurement in horizontal pipe. Experimental results showed that the soft-measurement method combined V-cone with adaptive wavelet network could satisfy the demand of the mass flow-rate measurement and the measurement error of the mass flow-rate was relatively small. The test results show fast learning, good adaptability, and faster processing time of the adaptive wavelet network and the measurement error of the total mass flow-rate was also acceptable. The method is attractive for possible applications in multi-phase flow measurement.
机译:提出了一种气/水质量流量的软测量方法,该方法采用了V-锥形差压计,并开发了自适应小波网络来实现对质量流量的软测量。采用多输入单输出模型来近似气/液的质量流率。本文着重于水平管道的实验测量。实验结果表明,将V-圆锥与自适应小波网络相结合的软测量方法可以满足质量流量测量的需求,质量流量的测量误差较小。测试结果表明,自适应小波网络学习速度快,适应性强,处理时间短,总质量流量的测量误差也可以接受。该方法对于多相流量测量中的可能应用具有吸引力。