In order to evaluate the effect of a chemical explosion test and to decide the safety of the test conditions, we used a highly precise and reliable measurement system to monitor it online to find out the leakage and diffusing of CO gas produced during the test in a special medium. For infilling explosion mode, we developed a monitor system based on electrochemical sensors which can be buried into the test medium directly without man-induced disturbance to acquire the data with less system error and distortion to replace the outdated pumping technique. The electrochemical sensors model 7E/F & 3F/D we used are produced by City Technology Limited. The results indicate that the monitoring system can work reliably within 144 hours during our test and the outputs are 1.5%~3% less than the actual CO concentration affected by pressure and temperature.
机译:为了评估化学爆炸测试的效果并确定测试条件的安全性,我们使用了高度精确且可靠的测量系统对其进行在线监控,以找出在测试过程中产生的CO气体的泄漏和扩散。特殊介质。对于填充爆炸模式,我们开发了一种基于电化学传感器的监测系统,该监测系统可以直接埋入测试介质中而不会受到人为干扰,从而以较少的系统误差和失真获取数据,以替代过时的泵送技术。我们使用的7E / F和3F / D型电化学传感器由City Technology Limited生产。结果表明,在测试过程中,监测系统可以在144小时内可靠地工作,其输出比受压力和温度影响的实际CO浓度低1.5%〜3%。