Unbalanced voltage sags strongly deteriorate the performance of power converters and electrical machines connected to the distribution network. In particular, a reduction of the power quality is noticed in these equipments, which is caused by a ripple in the output power and an increase of the current harmonic distortion. Several solutions based on reactive power compensation have been introduced to cope with this problem. Among them, static synchronous compensators have confirmed the superior performance due to the possibility of using all rated power exclusively to voltage support. This paper presents a simple reactive power control algorithm for static synchronous compensators operating under unbalanced voltage sags. The main feature of the proposed algorithm is that it allows a fine adjustment of the amount of reactive power injected by the positive- and negative-sequence components. Thus the control algorithm provides voltage support at the output of the static synchronous compensator. Specifically the proposed control conveniently corrects both the positive- and negative-sequence voltage. Selected simulation results are provided to validate the proposal.
机译:不平衡的电压骤降会严重降低连接到配电网络的功率转换器和电机的性能。特别地,在这些设备中注意到功率质量的下降,这是由于输出功率的波动和电流谐波失真的增加所引起的。为了解决这个问题,已经引入了几种基于无功功率补偿的解决方案。其中,由于可以将所有额定功率专用于电压支持,因此静态同步补偿器已经证实了其优越的性能。本文提出了一种在不平衡电压突降下工作的静态同步补偿器的简单无功功率控制算法。所提出算法的主要特征是它可以对正序和负序分量注入的无功功率进行微调。因此,控制算法在静态同步补偿器的输出端提供电压支持。特别地,所提出的控制方便地校正正序电压和负序电压。提供了选定的仿真结果以验证提案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号