In the last decades cardiovascular diseases greatly increased worldwide, and bioengineering provided new technologies and cardiovascular prostheses to medical doctors and surgeons. Ventricular assist devices aroused notable interests. As a consequence it is important to faithfully reproduce the interaction between the prostheses and the cardiovascular system when in-vitro experiments are performed. For this reason, a new and improved kind of test benches become necessary. In this paper an artiˉcial ventricle connected to a hydraulic circuit is described. The ventricle's control architecture is based on the estimation of some characteristic parameters. It is showed how this control strategy leads to the mutual interaction between the artificial ventricle and the hydraulic circuit and a correct mean atrial (preload) and aortic (afterload) pressure sensitivity and hydrodynamics.
机译:在过去的几十年中,心血管疾病在全世界范围内大大增加,生物工程为医生和外科医生提供了新技术和心血管修复术。心室辅助装置引起了极大的兴趣。因此,在进行体外实验时,忠实地再现假体与心血管系统之间的相互作用非常重要。因此,需要一种新的和改进的测试台。在本文中,描述了连接到液压回路的人工心室。心室的控制结构基于某些特征参数的估计。结果表明,这种控制策略如何导致人工心室和液压回路之间的相互影响,以及正确的平均心房(预负荷)和主动脉(后负荷)压力敏感性以及流体力学。